The P2 HSS High Security Sensor Switch is highly
resistant to external and internal magnetic
defeat. The sensors inside will detect the
presence of a stronger defeat magnet placed on
any surface of the HSS, and the removal tamper
circuit will alarm before the HSS can be removed.
The construction of the P2 HSS devices incorporates the patented, award winning Magnasphere switch technology. The electrical components and magnetic actuation are completely encapsulated with epoxy allowing the P2 HSS models to conform to the requirements of UL 913 and be used as an intrinsically safe simple apparatus device in hazardous locations.
WEB PRICING:
Stock number / Model#
2020410 / P2S-000 single contact @ $270.00
2020411 / P2S-001 single contact w/ 1K embedded
resistor @ $280.00
2020420 / P2D-000 dual contact @
$298.00
HIGH SECURITY SENSOR SWITCH POTTER P2 SERIES
UL 913 UL 634 LEVEL 2
Experts agree that the most devastating threats
to government and
corporate security have come from employees who
were deemed
trusted insiders. Armed with simple magnets,
unscrupulous insiders
can disable even triple-balanced BMS magnetic
contacts while the
system is unarmed, and enter undetected at a
later time, leaving no
evidence of tamper.
The P2 High Security Switch (HSS) combined with
Magnasphere
technology meets the UL 634 Level 2 High Security
Standard.
The P2 HSS meets standards for use with SCIF and
all other High
Security Applications. The P2 HSS is resistant to
external and internal
magnetic defeat. In addition, the switch resists
permanent contact
welding due to lightning, power surges, or stun
guns.
In addition to the sensors inside that will
detect the presence of a
stronger defeat magnet placed on any surface of
the HSS, the removal
tamper circuit will alarm before the HSS can be
removed.
The construction of the HSS devices incorporates
robust, hermetically
sealed Magnasphere switch technology as well as
complete epoxy
encapsulation of all electrical components and
magnetic actuation.
This allows the HSS models to conform to the
requirements of UL
913 and be used as an intrinsically safe simple
apparatus device in
hazardous locations. The P2 HSS devices must be
used in conjunction
with an intrinsically safe barrier.
Creative design of the P2 HSS switch itself
eliminates the need for L
or Z brackets.
SPECS:
Aluminum
Case: Silver grey anodized
Wire Lead Type: Solid color coded lead wires
Single Alarm Contact (P2S): Closed or open loop
Dual Alarm Contact (P2D): Closed loop
Removal Tamper Circuit: Closed loop
Max. Current: 0.25 A resistive
Max. Voltage: 30 VDC
Max. Power: 0.250 W
Operating Temperature: -40°F to 176°F (-40°C to
80°C)
• Listed to UL 634 Level 2 Standards
• Resistant to external and internal magnetic defeat
• Unique cross hole mounting feature eliminates need for L and Z
brackets on most installations
• Retrofit for existing BMS devices
• No adjustment required for installation
• Industry’s most secure removal tamper sensor/circuit
• May be used as an intrinsically safe simple apparatus
• Resists permanent contact welding (lightning, power surges, stun guns)
• Single and dual alarm contacts available
• Hermetically sealed switch contacts
• Fully epoxy potted assembly
• Indoor or outdoor use
Potter Stock Numbers 2020410 2020411 2020420
Potter Model Numbers P2S-000 P2S-001 P2D-000
High Security Sensors Switches Outdoor or Indoor Use.
Products may be discontinued without notice. Other disclaimers may apply. All trademarks remain the property of their respective holders, and are used only to directly describe the products being provided.